Scenic Acoustic & Vibration Engineering Ltd TEL: +44(0)1229 871171
info@scenicacoustic.co.uk
Eddy Current Inspection (EC)

Eddy Current Inspection (EC) is a technique used to detect surface breaking discontinuities in all electrically conducting materials. Uses include material sorting and in-service tube, bar and weld inspection. The main advantage is that testing can be conducted without the need to remove paint or surface coatings. Typical site applications include inspection of crane jibs, pedestals, pad-eyes (pre and post loading), drilling derrick substructures and wind turbine towers.

EC Theory

An alternating current is applied to an inspection coil, which creates a magnetic field. When placed next to a suitable test material, it induces an 'eddy current' into the test material. The presence of defects and material variations in the test material, affects the characteristics of the induced eddy currents. These changes are detected by an excitation coil and are displayed on a digital screen
CALL NOW on
01229 871171

Condition Monitoring
Acoustics
Vibrations
Predictive Maintenance
Equipment Hire


Scenic Acoustic & Vibration Engineering Ltd, 41 Clarence Road, Barrow-in-Furness, Cumbria, England, UK. LA14 9RT
Tel: 01229 871171 Mobile 07855 253 458
info@scenicacoustic.co.uk

(c)2018 Scenic Acoustic & Vibration Engineering Ltd